研究者業績

下村 義弘

シモムラ ヨシヒロ  (Yoshihiro Shimomura)

基本情報

所属
千葉大学 デザイン・リサーチ・インスティテュート 教授
学位
博士(工学)(千葉大学)

J-GLOBAL ID
200901059514570283
researchmap会員ID
5000023207

外部リンク

委員歴

 21

論文

 122
  • Kaiqi WEI, Chika KIMURA, Megumi SHIMURA, Yoshihiro SHIMOMURA, Xue ZHAO, Takaaki TAMURA, Shinichi SAKAMOTO
    The Japanese Journal of Ergonomics 61(1) 24-35 2025年2月15日  
  • Megumi Shimura, Akihiko Mizumoto, Yali Xia, Yoshihiro Shimomura
    Journal of physiological anthropology 42(1) 24-24 2023年10月27日  
    BACKGROUND: Surface electromyography (sEMG) is primarily used to analyze individual and neighboring muscle activity. However, using a broader approach can enable simultaneous measurement of multiple muscles, which is essential for understanding muscular coordination. Using the "bull's-eye electrode," which allows bipolar derivation without directional dependence, enables wide-area multipoint sEMG measurements. This study aims to establish a multipoint measurement system and demonstrate its effectiveness and evaluates forearm fatigue and created topographic maps during a grasping task. METHODS: Nine healthy adults with no recent arm injuries or illnesses participated in this study. They performed grasping tasks using their dominant hand, while bull's-eye electrodes recorded their muscle activity. To validate the effectiveness of the system, we calculated the root mean squares of muscle activity and entropy, an indicator of muscle activity distribution, and compared them over time. RESULTS: The entropy analysis demonstrated a significant time-course effect with increased entropy over time, suggesting increased forearm muscle uniformity, which is possibly indicative of fatigue. Topographic maps visually displayed muscle activity, revealing notable intersubject variations. DISCUSSION: Bull's-eye electrodes facilitated the capture of nine homogeneous muscle activity points, enabling the creation of topographic images. The entropy increased progressively, suggesting an adaptive muscle coordination response to fatigue. Despite some limitations, such as inadequate measurement of the forearm muscles' belly, the system is an unconventional measurement method. CONCLUSION: This study established a robust system for wide-area multipoint sEMG measurements using a bull's-eye electrode setup. This system effectively evaluates muscle fatigue and provides a comprehensive topographic view of muscle activity. These results mark a significant step towards developing a future multichannel sEMG system with enhanced measurement points and improved wearability. TRIAL REGISTRATION: This study was approved by the Ethics Committee of Chiba University Graduate School of Engineering (acceptance number: R4-12, Acceptance date: November 04, 2022).
  • Yali Xia, Yoshihiro Shimomura
    Ergonomics 66(3) 366-376 2023年3月  
    There are limited studies on monotonous task performance and its relationship with anxiety and stress traits. This study aimed to determine if local cooling exerts physiological effects and positively affects task performance. Ten male participants performed monotonous work for 24 min under control and local cooling conditions. We measured physiological arousal and anxiety using electroencephalography and the State-Trait Anxiety Inventory, respectively. The participants rated their drowsiness, the thermal sensation of the seat and whole-body thermal sensation. Despite the lack of significant differences in physiological arousal, the state anxiety score, which reflects the current stressful situation, was significantly lower in the local cooling condition. Therefore, cooling might help relieve stress during monotonous tasks, without impairing task performance. In addition, individuals with higher state anxiety scores tended to experience a faster increase in their arousal level. Thus, individual anxiety traits may modulate attentional resources during monotonous task performance.Practitioner summary: The study on topic related to monotonous task performance and its relationship with anxiety and stress traits is novel. Minimising negative emotions is key to monotonous task execution under stress. Individual anxiety might modulate resource allocation for monotonous task execution.
  • Hiroshi Kawahira, Ryoichi Nakamura, Yoshihiro Shimomura, Takashi Oshiro, Shinichi Okazumi, Alan K Lefor
    Asian journal of endoscopic surgery 14(1) 144-148 2021年1月  
    Surgeons have increased physical stress during laparoscopic surgery due to operative site constraints. We developed a wearable device to reduce the physical stress on surgeons' lower extremities. The device mechanically facilitates maintaining a near-upright posture. The surgeon's knees are gently bent by a knee-joint locking mechanism, and fixing and releasing are performed independently on each side. The subjects were one female and two male surgeons, who wore the device during laparoscopic inguinal hernia repair or high anterior resection. Surface electromyogram (EMG) was conducted for both iliopsoas muscles. Control values were determined with the subject not wearing the device. Participants completed a post-procedure questionnaire. With the device, EMG activity had a tendency to decrease in the left iliopsoas muscle (P = .055), but it changed little on the right (P = .406). The post-procedure questionnaire showed an overall positive impression, although subjects reported some difficulty walking. This device decreases EMG activity and may improve a surgeon's work environment.

MISC

 150

書籍等出版物

 20

講演・口頭発表等

 1
  • 下村義弘
    徳島大学選定研究クラスター主催 健幸社会を支えるIoTを活用した医療機器・健診ヘルスケアシステムの開発 医工連携講演会 2018年3月28日  招待有り

担当経験のある科目(授業)

 25

Works(作品等)

 1

共同研究・競争的資金等の研究課題

 18

産業財産権

 45

社会貢献活動

 35