大学院医学研究院

木村 青児

キムラ セイジ  (Seiji Kimura)

基本情報

所属
千葉大学 大学院医学研究院整形外科学先端脊椎関節機能再建医学講座 特任助教

研究者番号
80876897
J-GLOBAL ID
202001017791771990
researchmap会員ID
R000001645

論文

 124
  • Takuya Sakamoto, Shotaro Watanabe, Manato Horii, Ryu Ito, Seiji Kimura, Satoshi Yamaguchi, Seiji Ohtori, Takahisa Sasho
    Cureus 2024年9月30日  
  • Ryu Ito, Shotaro Watanabe, Takuya Sakamoto, Kaoru Toguchi, Manato Horii, Seiji Kimura, Satoshi Yamaguchi, Seiji Ohtori, Takahisa Sasho
    Cureus 2024年9月23日  
  • Yuriko Yoshimoto, Satoshi Yamaguchi, Seiji Kimura, Kaoru Kitsukawa, Koji Matsumoto, Yuki Shiko, Manato Horii, Shotaro Watanabe, Takahisa Sasho, Seiji Ohtori
    Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association 2024年8月19日  
    BACKGROUND: We aimed to evaluate the intra- and interrater measurement reliability of the lateral ankle ligament attachment locations using three-dimensional magnetic resonance imaging. METHODS: We analysed 54 participants with a mean age of 43 years who underwent three-dimensional ankle magnetic resonance imaging and had normal lateral ligaments. Bony landmarks of the distal fibula, talus, and calcaneus were identified in the reconstructed images. The centers of the anterior talofibular ligament and calcaneofibular ligament attachments were also identified. The distances between the landmarks and attachments were measured. Two raters performed the measurements twice, and intra- and interrater intraclass correlation coefficients were calculated. RESULTS: The intrarater intraclass correlation coefficient values were between 0.71 and 0.96 for the anterior talofibular ligament attachment measurements and between 0.77 and 0.95 for the calcaneofibular ligament attachments. The interrater intraclass correlation coefficient was higher than 0.7, except for the distance between the anterior talofibular ligament superior bundle and fibular obscure tubercle. The fibular attachment of a single-bundle anterior talofibular ligament was located 13.3 mm from the inferior tip and 43% along the anterior edge of the distal fibula. The superior and inferior bundles of the double-bundle ligament were located at 43% and 23%, respectively. The calcaneofibular ligament fibular attachment was 5.5 mm from the inferior tip, at 16% along the anterior edge of the distal fibula. CONCLUSION: The measurements of anterior talofibular ligament and calcaneofibular ligament attachment locations identified on three-dimensional magnetic resonance imaging were sufficiently reliable. This measurement method provides in vivo anatomical data on the lateral ankle ligament anatomy.
  • Toshinari Mashu, Satoshi Yamaguchi, Seiji Kimura, Hirofumi Nakajima, Manato Horii, Shotaro Watanabe, Ryu Ito, Takahisa Sasho, Seiji Ohtori
    Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons 2024年7月14日  
    BACKGROUND: Clamping along the transsyndesmotic (TS) axis decreases the risk of malreduction when reducing syndesmotic diastasis. We aimed to measure the difference between the TS axis and the axis determined by the newly proposed fluoroscopic incisura tangent (IT) method. The measurements were compared to those between the TS axis and those based on the center-center (CC) and talar dome lateral (TL) methods. METHODS: We analyzed computed tomographic images of 43 normal ankles. The IT view was simulated using a digitally reconstructed radiograph, in which the anterior and posterior fibular incisura tubercles overlapped on the internally rotated anteroposterior view. The interaxis angle between the TS and the axes determined by the IT method was measured on the axial computed tomographic image corresponding to the radiographic image. The same procedure was repeated using the CC and TL methods. The measured values were compared between the three methods using a one-factor analysis of variance. Furthermore, the measurements of the anteverted and retroverted incisurae were compared for each fluoroscopic method. RESULTS: The mean interaxis angles between the TS were - 0.5 degrees, 6.3 degrees, and - 1.8 degrees for the IT, CC, and TL methods, respectively, with a significantly larger value for the CC method than for the IT and TL methods (P < .001). No significant difference was found in the interaxis angle in the anteverted (-0.1 degrees) and retroverted (-1.0 degrees) incisurae when using the IT method (P = .15). The angles in the retroverted incisurae were larger than those of the anteverted incisurae for the CC and TL methods. CONCLUSION: The fluoroscopic IT method accurately estimated the TS axis. The interaxis angles were consistent, regardless of the incisura anatomy. The fluoroscopic method can be used to clamp and fix the syndesmosis along the TS axis. LEVEL OF EVIDENCE: Ⅳ.
  • Takuya Sakamoto, Manato Horii, Shotaro Watanabe, Ryu Ito, Ryuichiro Akagi, Hiroaki Hosokawa, Seiji Kimura, Satoshi Yamaguchi, Seiji Ohtori, Takahisa Sasho
    Cureus 16(7) e64357 2024年7月  
    Introduction Restoring knee joint stability and resuming sports activities are important objectives of anterior cruciate ligament (ACL) reconstruction. The maintenance of anterior knee stability after ACL reconstruction is contingent on graft tension. Various devices and techniques have been used to achieve robust tibial graft tendon fixation, and their advantages and disadvantages are established. However, a gold standard has not been established. Therefore, we aimed to determine whether anterior knee joint stability and clinical outcomes of graft tendon fixation could be improved using a recently modified suture button (MSB) compared with using an adjustable suspensory fixator (ASF) at 1 year after double-bundle ACL reconstruction. Methods This study retrospectively analyzed postoperative data derived from 79 patients at a single center between January 2016 and December 2021. The patients were assigned to groups that underwent double-bundle ACL reconstruction with tibial fixation using an MSB (n = 30) that maintains tension while tying sutures, or an ASF (n = 49). We then compared complications, clinical outcomes and knee joint stability at 1 year postoperatively. Rates of postoperative infection, graft rupture, implant removal and residual anterior knee laxity (AKL) were compared between the groups using chi-square tests. Patient-reported outcome measures (PROM) based on Forgot Joint Score-12, Knee Injury and Osteoarthritis Outcome, and Lysholm Knee scores were compared using Mann-Whitney U tests. Results One patient in the MSB group developed postoperative infection. Rates of graft rupture and implant removal in the MSB and ASF groups were 3.3% and 4.1%, and 3.6% and 10.2%, respectively. None of the PROMs differed between the groups. The proportions of postoperative AKL were 3.6% and 14.9% in the MSB and ASF groups, respectively. A trend towards lower postoperative AKL in the MSB group did not reach statistical significance (p = 0.25). Conclusions The incidence of AKL at a year after ACL reconstruction using the MSB was 3%. Postoperative AKL and clinical outcomes were comparable between the MSB and ASF groups. A low AKL rate and positive postoperative outcomes indicated that MSB could be an option for tibial-side fixation in ACL reconstruction.

MISC

 15

共同研究・競争的資金等の研究課題

 1