大学院工学研究院

小川 良磨

オガワ リョウマ  (Ryoma Ogawa)

基本情報

所属
千葉大学 大学院工学研究院 特任助教

J-GLOBAL ID
202401008742503441
researchmap会員ID
R000065473

経歴

 1

論文

 8
  • Arbariyanto Mahmud Wicaksono, Daisuke Kawashima, Ryoma Ogawa, Shinsuke Akita, Masahiro Takei
    Biomedical physics & engineering express 11(2) 2025年1月31日  
    Albumin andγ-globulin concentrations in subcutaneous adipose tissues (SAT) have been quantified by multivariate regression based on admittance relaxation time distribution (mrARTD) under the fluctuated background of sodium electrolyte concentration. ThemrARTD formulatesP=Ac+Ξ(P: peak matrix of distribution function magnitudeγˆand relaxation timesτˆ,c: concentration matrix of albumincAlb,γ-globulinGloc, and sodium electrolyteNac,A: coefficient matrix of a multivariate regression model, andΞ: error matrix). ThemrARTD is implemented by two processes which are: (1) the training process ofAthrough the maximum likelihood estimation ofPand (2) the quantification process ofcAlb,Gloc, andNacthrough the model prediction. In the training process, a positive correlation is present betweencAlb,Gloc, andNactoγˆ1atτˆ1= 0.1 as well asγˆ2atτˆ2= 1.40 μs as under a fixed concentration of proteins solution into a porcine SAT (cAlb= 0.800-2.400 g/dL,Gloc= 0.400-1.200 g dl-1andNac= 0.700-0.750 g dl-1). ThemrARTD method quantifiescAlb,Gloc, andNacin SAT with an absolute error of 33.79%, 44.60%, and 2.18%, respectively.
  • Galih Setyawan, Prima Asmara Sejati, Ryoma Ogawa, Kiagus Aufa Ibrahim, Hiroshi Fujimoto, Hiroto Yamamoto, Masahiro Takei
    Biomedical physics & engineering express 10(5) 2024年7月11日  
    Invasive ductal carcinoma (IDC) in breast specimens has been detected in the quadrant breast area: (I) upper outer, (II) upper inner, (III) lower inner, and (IV) lower outer areas by electrical impedance tomography implemented with Gaussian relaxation-time distribution (EIT-GRTD). The EIT-GRTD consists of two steps which are (1) the optimum frequencyfoptselection and (2) the time constant enhancement of breast imaging reconstruction.foptis characterized by a peak in the majority measurement pair of the relaxation-time distribution functionγ,which indicates the presence of IDC.γrepresents the inverse of conductivity and indicates the response of breast tissues to electrical currents across varying frequencies based on the Voigt circuit model. The EIT-GRTD is quantitatively evaluated by multi-physics simulations using a hemisphere container of mimic breast, consisting of IDC and adipose tissues as normal breast tissue under one condition with known IDC in quadrant breast area II. The simulation results show that EIT-GRTD is able to detect the IDC in four layers atfopt= 30, 170 Hz. EIT-GRTD is applied in the real breast by employed six mastectomy specimens from IDC patients. The placement of the mastectomy specimens in a hemisphere container is an important factor in the success of quadrant breast area reconstruction. In order to perform the evaluation, EIT-GRTD reconstruction images are compared to the CT scan images. The experimental results demonstrate that EIS-GRTD exhibits proficiency in the detection of the IDC in quadrant breast areas while compared qualitatively to CT scan images.
  • Ryoma Ogawa, Shinsuke Akita, Masahiro Takei
    IEEE Transactions on Instrumentation and Measurement 72 1-14 2022年11月  筆頭著者
  • 小川良磨, 秋田新介, 武居昌宏
    日本機械学会論文集 88(910) 22-00090 2022年6月  筆頭著者

MISC

 1

講演・口頭発表等

 17